| Efficiency | 
			typ. 94.7 % (24 V DC) | 
		
		
			| Output characteristic | 
			U/I Advanced | 
		
		
			| Smart HICCUP | 
		
		
			| FUSE MODE | 
		
		
			| Nominal output voltage | 
			24 V DC | 
		
		
			| Setting range of the output voltage (USet) | 
			24 V DC ... 29.5 V DC (> 24 V DC, constant capacity) | 
		
		
			| Nominal output current (IN) | 
			20 A | 
		
		
			| Static Boost (IStat.Boost) | 
			25 A | 
		
		
			| Dynamic Boost (IDyn.Boost) | 
			30 A (5 s) | 
		
		
			| Selective Fuse Breaking (ISFB) | 
			120 A (15 ms) | 
		
		
			| Magnetic circuit breaker tripping | 
			A1...A16 / B2...B13 / C1...C6 / Z1...Z16 | 
		
		
			| Short-circuit-proof | 
			yes | 
		
		
			| No-load proof | 
			yes | 
		
		
			| Output power (PN) | 
			480 W | 
		
		
			| Output power (PStat. Boost) | 
			600 W | 
		
		
			| Output power (PDyn. Boost) | 
			720 W (5 s) | 
		
		
			| Feedback voltage resistance | 
			≤ 35 V DC | 
		
		
			| Protection against overvoltage at the output (OVP) | 
			≤ 32 V DC | 
		
		
			| Residual ripple | 
			< 50 mVPP | 
		
		
			| Control deviation | 
			< 3 % (change in load, static 10 % ... 90 %) | 
		
		
			| Control deviation | 
			< 3 % (change in load, static 10 % ... 90 %) | 
		
		
			| Control deviation | 
			< 3 % (change in load, static 10 % ... 90 %) | 
		
		
			| Rise time | 
			< 100 ms (UOUT (10 % ... 90 %)) | 
		
		
			| Connection in series | 
			yes | 
		
		
			| Maximum no-load power dissipation | 
			< 4 W | 
		
		
			| Power loss nominal load max. | 
			< 26.6 W | 
		
		
			| Power dissipation SLEEP MODE | 
			< 2 W | 
		
		
			| Connection in parallel | 
			yes, for redundancy and increased capacity | 
		
		
			| Signal Out 1 (configurable) | 
		
		
			| Connection labeling | 
			3.5 + | 
		
		
			| Digital | 
			0 V DC | 
		
		
			| 24 V DC | 
		
		
			| 20 mA | 
		
		
			| Signal option | 
			Output voltage | 
		
		
			| Output current | 
		
		
			| Output power | 
		
		
			| Operating hours | 
		
		
			| Early warning of high temperatures | 
		
		
			| OVP voltage limitation active | 
		
		
			| Default | 
			UIN input voltage OK | 
		
		
			| Signal Out 2 (configurable) | 
		
		
			| Connection labeling | 
			3.6 + | 
		
		
			| Digital | 
			0 V DC | 
		
		
			| 24 V DC | 
		
		
			| 20 mA | 
		
		
			| Default | 
			Output power | 
		
		
			| Signal option | 
			Output voltage | 
		
		
			| Output current | 
		
		
			| Operating hours | 
		
		
			| Early warning of high temperatures | 
		
		
			| OVP voltage limitation active | 
		
		
			| Analog | 
			4 mA ... 20 mA ±5 % (Load ≤400 Ω) | 
		
		
			| Signal option | 
			Output voltage | 
		
		
			| Output current | 
		
		
			| Output power | 
		
		
			| Signal relay 13/14 (configurable) | 
		
		
			| Connection labeling | 
			3.1, 3.2 | 
		
		
			| Switch contact (floating) | 
			floating | 
		
		
			| Maximum contact load | 
			24 V DC | 
		
		
			| 1 A | 
		
		
			| 30 V AC | 
		
		
			| 0.5 A | 
		
		
			| Default | 
			Output voltage | 
		
		
			| Signal option | 
			Output current | 
		
		
			| Output power | 
		
		
			| Operating hours | 
		
		
			| Early warning of high temperatures | 
		
		
			| OVP voltage limitation active | 
		
		
			| UIN input voltage OK | 
		
		
			| Signal ground SGnd | 
		
		
			| Connection labeling | 
			3.4 + | 
		
		
			| Function | 
			Signal ground | 
		
		
			| Reference potential | 
			to OUT1, OUT2, REM |