Efficiency |
typ. 94.7 % (24 V DC) |
Output characteristic |
U/I Advanced |
Smart HICCUP |
FUSE MODE |
Nominal output voltage |
24 V DC |
Setting range of the output voltage (USet) |
24 V DC ... 29.5 V DC (> 24 V DC, constant capacity) |
Nominal output current (IN) |
20 A |
Static Boost (IStat.Boost) |
25 A |
Dynamic Boost (IDyn.Boost) |
30 A (5 s) |
Selective Fuse Breaking (ISFB) |
120 A (15 ms) |
Magnetic circuit breaker tripping |
A1...A16 / B2...B13 / C1...C6 / Z1...Z16 |
Short-circuit-proof |
yes |
No-load proof |
yes |
Output power (PN) |
480 W |
Output power (PStat. Boost) |
600 W |
Output power (PDyn. Boost) |
720 W (5 s) |
Feedback voltage resistance |
≤ 35 V DC |
Protection against overvoltage at the output (OVP) |
≤ 32 V DC |
Residual ripple |
< 50 mVPP |
Control deviation |
< 3 % (change in load, static 10 % ... 90 %) |
Control deviation |
< 3 % (change in load, static 10 % ... 90 %) |
Control deviation |
< 3 % (change in load, static 10 % ... 90 %) |
Rise time |
< 100 ms (UOUT (10 % ... 90 %)) |
Connection in series |
yes |
Maximum no-load power dissipation |
< 4 W |
Power loss nominal load max. |
< 26.6 W |
Power dissipation SLEEP MODE |
< 2 W |
Connection in parallel |
yes, for redundancy and increased capacity |
Signal Out 1 (configurable) |
Connection labeling |
3.5 + |
Digital |
0 V DC |
24 V DC |
20 mA |
Signal option |
Output voltage |
Output current |
Output power |
Operating hours |
Early warning of high temperatures |
OVP voltage limitation active |
Default |
UIN input voltage OK |
Signal Out 2 (configurable) |
Connection labeling |
3.6 + |
Digital |
0 V DC |
24 V DC |
20 mA |
Default |
Output power |
Signal option |
Output voltage |
Output current |
Operating hours |
Early warning of high temperatures |
OVP voltage limitation active |
Analog |
4 mA ... 20 mA ±5 % (Load ≤400 Ω) |
Signal option |
Output voltage |
Output current |
Output power |
Signal relay 13/14 (configurable) |
Connection labeling |
3.1, 3.2 |
Switch contact (floating) |
floating |
Maximum contact load |
24 V DC |
1 A |
30 V AC |
0.5 A |
Default |
Output voltage |
Signal option |
Output current |
Output power |
Operating hours |
Early warning of high temperatures |
OVP voltage limitation active |
UIN input voltage OK |
Signal ground SGnd |
Connection labeling |
3.4 + |
Function |
Signal ground |
Reference potential |
to OUT1, OUT2, REM |