Efficiency |
> 80 % (for 230 V AC and nominal values) |
Output characteristic |
U/I |
Nominal output voltage |
5 V DC ±1 % |
Setting range of the output voltage (USet) |
4 V DC ... 6.5 V DC (> 5 V DC, constant capacity restricted) |
Output current Imax |
11.5 A |
Nominal output current (IN) |
6.5 A (-25 °C ... 55 °C) |
7.1 A (-25 °C ... 40 °C permanent) |
Derating |
55 °C ... 70 °C (2.5%/K) |
Feedback voltage resistance |
≤ 10 V DC |
Protection against overvoltage at the output (OVP) |
< 10 V DC |
Control deviation |
< 1 % (change in load, static 10 % ... 90 %) |
< 2 % (change in load, dynamic 10 % ... 90 %) |
< 0.1 % (change in input voltage ±10 %) |
Residual ripple |
< 50 mVPP (20 MHz) |
Output power |
32.5 W |
Peak switching voltages nominal load |
< 40 mVPP (20 MHz) |
Maximum no-load power dissipation |
< 0.4 W |
Power loss nominal load max. |
8.1 W |
Rise time |
< 0.5 s (UOUT (10 % ... 90 %)) |
Connection in parallel |
yes, for redundancy and increased capacity |
Connection in series |
yes |