Valve function |
2x2/2 closed, monostable
2x2/2 open/closed, monostable
2x3/2 closed, monostable
2x3/2 open, monostable
2x3/2 open/closed, monostable
5/2 bistable
5/2 monostable
Vacuum generator
Vacuum generator + 2/2 closed, single solenoid |
Valve size |
10 mm |
Max. standard nominal flow rate |
400 l/min at 10 mm |
Operating pressure |
-0.9 ... 10 bar |
Electrical connection |
AS-Interface
CPI installation system
Individual connection
Fieldbus
Multi-pin plug |
Max. number of valve positions |
8 |
Max. no. of pressure zones |
2 |
Electrical I/O system |
Yes |
Ambient temperature |
-5 ... 50 °C |
Protection class |
IP65 |
Authorisation |
RCM Mark
c UL us - Recognized (OL) |
KC mark |
KC-EMV |
CE mark (see declaration of conformity) |
to EU directive for EMC
to EU directive explosion protection (ATEX) |
Explosion protection certification outside the EU |
NEC 500 Class I, Div. 2 |
ATEX category Gas |
II 3G |
Explosion ignition protection type Gas |
Ex nA IIC T4 X Gc |
Explosion-proof ambient temperature |
-5°C <= Ta <= +50°C |
Nominal size |
4 mm |
Type of actuation |
electrical |
Sealing principle |
soft |
Valve terminal type |
10 |
Design structure |
Piston slide |
Max. no. of valve functions |
16 |
Pilot air supply |
external
Internal |
Valve terminal structure |
Fixed-grid |
Signal status display |
LED |
Note on operating pressure |
0 - 8 bar with external pilot air |
Pilot pressure |
3 ... 8 bar |
Suitability for vacuum |
Yes |
Nominal operating voltage DC |
24 V |
Operating medium |
Compressed air in accordance with ISO8573-1:2010 [7:4:4] |
Note on operating and pilot medium |
Lubricated operation possible (subsequently required for further operation) |
Vibration resistance |
Transport application test at severity level 2 in accordance with FN 942017-4 and EN 60068-2-6 |
Shock resistance |
Shock test with severity level 2 in accordance with FN 942017-5 and EN 60068-2-27 |
Corrosion resistance classification CRC |
1 - Low corrosion stress
2 - Moderate corrosion stress |
Storage temperature |
-20 ... 40 °C |
Medium temperature |
-5 ... 50 °C |
Auxiliary pilot air port 12/14 |
Common line |
Pilot exhaust port 82/84 |
Common line |
Pneumatic connection, port 1 |
Common line |
Pneumatic connection, port 2 |
M7 |
Pneumatic connection, port 3 |
Common line |
Pneumatic connection, port 4 |
M7 |
Materials note |