Feature | Value |
---|---|
Shipping date | View |
Vision sensor version | Code reader |
CE mark (see declaration of conformity) | to EU directive for EMC |
KC mark | KC-EMV |
Authorisation | RCM Mark c UL us - Listed (OL) |
Field of vision | Dependent on the selected lens |
Lens attachment | CS-Mount |
Lighting type | Integrated |
Sensor type | monochrome |
Sensor resolution | 1280 x 1024 Pixel (SXGA) |
Image rate (frame) | 40 fps |
Max. number of test programs/jobs | 255 |
Max. number of test criteria/detectors | 255 |
Function of detectors/characteristics | EAN UPC RSS 2/5 Interleaved 2/5 Industrial Code 39 Code 93 Code 128 GS1 Pharmacode Codabar ECC200 QR-Code PDF 417 |
Typical cycle time | 1D-Barcode: 30 ms 2D-Code: 40 ms |
Information on Ethernet, connection technology | Socket M12 4-pin |
Ethernet, data transmission speed | 100 Mbit/s |
Ethernet, supported protocols | Ethernet/IP FTP PROFINET SMB TCP/IP |
Serial interface, connection technology | Plug M12 5-pin |
Serial interface, type | RS 232 / RS 422 |
Electrical connection | Plug M12 12-pin |
Number of digital inputs | 2 |
Number of digital outputs | 2 |
Number of selectable digital inputs/outputs | 4 |
Switching input | PNP/NPN, switchable |
Switching level | Signal 0: <= 3 V Signal 1: >= UB - 1 V |
Switch output | PNP/NPN, switchable |
Max. output current | 50 mA |
Short circuit strength | for all electrical connections |
Nominal operating voltage DC | 24 V |
Permissible voltage fluctuation | -25 % / +10 % |
Max. current consumption | 550 mA |
Current consumption with load-free outputs | 200 mA |
Ambient temperature | 0 ... 50 °C |
Storage temperature | -20 ... 60 °C |
Protection class | IP65 |
Note on degree of protection | With protective tube |
Dimensions W x L x H | 45 mm x 45 mm x 76,7 mm |
Product weight | 160 g |
Material housing | Anodised wrought aluminium alloy |
Material cover | ABS-reinforced |
Materials note | Conforms to RoHS |
Vibration resistance | as per EN 60068-2-6 |
Shock resistance | Shock test with severity level 2 in accordance with FN 942017-5 and EN 60068-2-27 |