Feature | Value |
---|---|
Nominal size | 4 mm |
Type of actuation | electrical |
Sealing principle | Hard |
Assembly position | Any Preferably horizontal (display components upwards) If the valve is moved, it must be mounted at a right angle to the direction of movement |
Design structure | Piston slide With built-in pressure sensors |
Type of reset | Magnetic spring |
Safety instructions | Safety position VPWP |
Type of piloting | direct |
Flow direction | non reversible |
Valve function | 5/3 proportional directional control valve, closed |
Status displays | LED yellow = PL (power load) LED green = power LED red = error |
Operating pressure | 0 ... 10 bar |
Operating pressure, positioning / soft stop | 4 ... 8 bar |
Nominal operating pressure | 6 bar |
Standard nominal flow rate | 350 l/min |
Nominal operating voltage DC | 24 V |
Operating voltage range DC | 18 ... 30 V |
Load voltage range DC | 18 ... 30 V |
Max. load current of the voltage output | 500 mA |
Max. load current of the digital output | 500 mA |
Max. current consumption of valve drive | 1.2 A |
Max. current consumption, logic | 0.15 A |
Nominal voltage DC | 24 V |
Supply voltage of the digital output | 24 V load voltage |
Supply voltage of the voltage output | 24 V load voltage |
Authorisation | RCM Mark |
CE mark (see declaration of conformity) | to EU directive for EMC to EU directive explosion protection (ATEX) |
ATEX category Gas | II 3G |
Explosion ignition protection type Gas | Ex nA IIC T5 X Gc |
Explosion-proof ambient temperature | 0°C <= Ta <= +50°C |
Operating medium | Compressed air in accordance with ISO8573-1:2010 [6:4:4] |
Note on operating and pilot medium | Lubricated operation not possible |
Corrosion resistance classification CRC | 1 - Low corrosion stress |
Medium temperature | 0 ... 50 °C |
Protection class | IP65 in assembled condition |
Ambient temperature | 0 ... 50 °C |
Product weight | 776 g |
Resolution pressure | 0.01 bar |
Linearity error, FS | < 1.5 % |
FS repetition accuracy | < 1 % |
Design of the 24 V voltage output | Positive logic (PNP) No electrical isolation Protected against short circuits Return supply without damage |
Design of the digital output | Per IEC 61131-2 Positive logic (PNP) No electrical isolation Protected against short circuits Return supply without damage |
Control interface | Digital CAN bus with Festo protocol Terminating resistor, integrated |
Electrical connection, fieldbus interface IN | Plug M9 5-pin |
Electrical connection, fieldbus interface OUT | Plug socket M9 5-pin |
Fieldbus interface electrical connection | Plug socket M8 4-pin |
Mounting type | with through hole with accessories |
Colour of connections | Connection 2: Blue Connection 4: Black |
Pneumatic connection, port 1 | G1/8 |
Pneumatic connection, port 2 | G1/8 |
Pneumatic connection, port 3 | G1/8 |
Pneumatic connection, port 4 | G1/8 |
Pneumatic connection, port 5 | G1/8 |