Country of origin DE (Germany)
Ambient conditions
Ambient temperature (operation) -40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Maximum altitude ≤ 2000 m
Degree of protection IP00
≥ IP54 (Installation location)
Back to top
General
Max. permissible operating voltage 25 V AC
60 V DC
Max. current carrying capacity per path 1 A (50 °C)
0.6 A (70°C)
Length of cable 1 m
External cable diameter 6.1 mm ±0.4 mm
Single wire, cross section 0.14 mm²
Single wire, cross section [AWG] 26
Single wire, number of litz wires 7
Single wire, material Cu tin-plated
Wire diameter incl. insulation 1 mm ±0.03 mm
Smallest bending radius, fixed installation 52 mm
Smallest bending radius, movable installation 98 mm
Connection data
Connection name Field level
Connection in acc. with standard IEC 60603-13
Connection method IDC/FLK socket strip
Number of connections 1
Number of positions 14
Exit angle 90 °
Conductor cross section AWG 26
Insertion/withdrawal cycles > 50
Connection data 2
Connection name Controller level
Connection method Single wires
Number of positions 8
Note The wires are marked and fitted with ferrules